Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 22(2): 131-142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36511024

RESUMO

Aim: The aim of the study is to systematically assess the impact of low-temperature degradation (LTD) simulation in an autoclave on mechanical and microstructural properties of infiltrated monolithic zirconia compared to the noninfiltrated zirconia. Settings and Design: Systematic review following Preferred Reporting Items for Systematic Reviews and Meta-Analysis 2020 guidelines. Materials and Methods: An electronic search was done within these databases: PubMed, Scopus, and Web of Science, Science Direct, Embase, Wiley, Google Scholar for articles published between 2000 and March 2021. Search results that met eligibility criteria were categorized into two groups based on properties assessed of infiltrated monolithic zirconia exposed to LTD (also called aging simulation) - (a) mechanical (flexural strength and fracture toughness) and (b) microstructural properties (phase transformation rate and m content). Statistical Analysis Used: Qualitative analysis. Results: The search identified 272 preliminary results. After discarding duplicates, and screening of titles, abstracts, and full texts, 10 articles finally met inclusion criteria. Data were collected on author's details and their countries, journal and year of publication, type and percentage of infiltration, aging protocol (duration and temperature), mechanical, and microstructural properties. All the included studies invariably revealed better aging resistance without a change in mechanical properties for infiltrated monolithic zirconia as compared to noninfiltrated species. Conclusion: Infiltration within monolithic zirconia can reduce degradation and simultaneously maintain their mechanical properties by preventing water entry into grain contours. The final m content was less for infiltrated Zirconium, indicating a lesser phase transformation and better aging resistance. Other Information: Systematic review protocol registered at PROSPERO CRD42021248153.


Assuntos
Cerâmica , Zircônio , Cerâmica/química , Teste de Materiais , Zircônio/química , Resistência à Flexão
2.
Dental Press J Orthod ; 26(2): e212020, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33950083

RESUMO

INTRODUCTION: After debonding, white spot may appear on the area below the bracket, which is the early clinical sign of carious lesion. There is increased caries risk underneath and adjacent to orthodontic bands and brackets, which call for maximum use of caries preventive procedures using various fluoride application methods. OBJECTIVE: The aim of the study was to evaluate alterations in the mechanical properties (modulus of elasticity and yield strength) in loading and unloading phases for different orthodontic archwires (nickel-titanium [NiTi] and copper-nickel-titanium [CuNiTi]) when exposed routinely to fluoride prophylactic agents for a predetermined period of time. METHODS: Preformed rectangular NiTi and CuNiTi wires were immersed in fluoride solution and artificial saliva (control) for 90 minutes at 37ºC. After immersion, specimens were tested using a 3-point bend test on a universal testing machine. RESULTS: There is a significant reduction in the unloading yield strength when the NiTi and CuNiTi wires were exposed to APF gel. CONCLUSION: The result suggests that use of topical fluoride agents affect the mechanical properties of the wires, leading to increase in treatment duration. Fluoride prophylactic agents must be used with caution in patients undergoing orthodontic treatment. Injudicious use of these agents may cause corrosive effects on the orthodontic wire surfaces, with alteration in their mechanical properties.


Assuntos
Níquel , Fios Ortodônticos , Cobre , Ligas Dentárias , Fluoretos , Humanos , Teste de Materiais , Níquel/efeitos adversos , Propriedades de Superfície , Titânio
3.
Dental press j. orthod. (Impr.) ; 26(2): e212020, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1249707

RESUMO

ABSTRACT Introduction: After debonding, white spot may appear on the area below the bracket, which is the early clinical sign of carious lesion. There is increased caries risk underneath and adjacent to orthodontic bands and brackets, which call for maximum use of caries preventive procedures using various fluoride application methods. Objective: The aim of the study was to evaluate alterations in the mechanical properties (modulus of elasticity and yield strength) in loading and unloading phases for different orthodontic archwires (nickel-titanium [NiTi] and copper-nickel-titanium [CuNiTi]) when exposed routinely to fluoride prophylactic agents for a predetermined period of time. Methods: Preformed rectangular NiTi and CuNiTi wires were immersed in fluoride solution and artificial saliva (control) for 90 minutes at 37ºC. After immersion, specimens were tested using a 3-point bend test on a universal testing machine. Results: There is a significant reduction in the unloading yield strength when the NiTi and CuNiTi wires were exposed to APF gel. Conclusion: The result suggests that use of topical fluoride agents affect the mechanical properties of the wires, leading to increase in treatment duration. Fluoride prophylactic agents must be used with caution in patients undergoing orthodontic treatment. Injudicious use of these agents may cause corrosive effects on the orthodontic wire surfaces, with alteration in their mechanical properties.


RESUMO Introdução: Após a remoção dos braquetes, manchas brancas podem aparecer na área embaixo deles, as quais são o sinal clínico inicial da lesão cariosa. Existe um maior risco de cáries embaixo e ao redor das bandas e braquetes ortodônticos, o que exige a máxima utilização de procedimentos preventivos de cárie, usando diferentes métodos com aplicação de flúor. Objetivo: O objetivo do presente estudo foi avaliar alterações nas propriedades mecânicas (módulo de elasticidade e resistência ao escoamento), nas fases de carregamento e descarregamento de diferentes fios ortodônticos (níquel-titânio [NiTi] e níquel-titânio com adição de cobre [CuNiTi]), quando expostos rotineiramente a agentes profiláticos fluoretados, utilizados durante um período de tempo predeterminado. Métodos: Os fios pré-contornados retangulares de NiTi e CuNiTi foram imersos em solução fluoretada e saliva artificial (controle) durante 90 minutos a 37°C. Após a imersão, as amostras foram testadas utilizando-se um teste de flexão em três pontos, em uma máquina universal de testes. Resultados: Houve uma redução significativa na resistência ao escoamento na fase de descarregamento quando os fios de NiTi e CuNiTi foram expostos ao gel fluoretado. Conclusão: O resultado sugere que o uso tópico de agentes fluoretados afeta as propriedades mecânicas dos fios, levando a um aumento na duração do tratamento. Os agentes profiláticos fluoretados devem ser utilizados com cautela em pacientes submetidos a tratamento ortodôntico. O uso indiscriminado desses agentes pode causar efeitos corrosivos na superfície dos fios ortodônticos e consequente alteração das suas propriedades mecânicas.


Assuntos
Humanos , Fios Ortodônticos , Cobre , Ligas Dentárias , Fluoretos , Níquel , Propriedades de Superfície , Titânio , Teste de Materiais , Níquel/efeitos adversos
4.
J Indian Prosthodont Soc ; 20(1): 97-103, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32089605

RESUMO

AIMS: This study aimed to analyze the effect of different investment techniques and pattern materials on the surface roughness of raw castings from nickel-chromium alloy. SETTINGS AND DESIGN: This is an experimental in vitro study carried out in Bharati Vidyapeeth Dental College and Hospital, Sangli, Maharastra. MATERIALS AND METHODS: Sixty square-shaped wax patterns, measuring 10 mm × 10 mm × 2 mm, were divided into four groups. A phosphate-bonded investment material (Bellasun, Bego, Germany) was used to invest 15 samples of inlay wax and kept under normal atmospheric pressure and the remaining 15 wax patterns were invested under a pressure of 3 bars for 30 min, and then allowed to bench set for another 30 min. The same investing techniques were carried out for the remaining thirty samples made from pattern resin. STATISTICAL ANALYSIS USED: The surface roughness (µm) of the castings was measured by a profilometer. Student's "unpaired t-test" was used for the statistical analysis. RESULTS: Specimens that were invested at atmospheric pressure had significantly more surface roughness (µm) values than those invested under increased pressure (P < 0.01). CONCLUSIONS: Wax patterns exhibited the least surface roughness when invested under pressure and can be recommended as the material and technique of choice. In addition, resin patterns invested under increased pressure produced smoother casting surface than those invested at atmospheric pressure, and the difference is highly significant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...